SMART RELAY SREL, SREL.ZK, SREL.ADV
6
Warning
! Do not use switching power supplies near Smart Relays. All mains adaptors
are to be provided by the customer; they cannot be acquired from SimonsVoss.
3.4 YOU NEED TO DETERMINE THE INSTALLATION LOCATION
The transponder transmission range for Smart Relay (read range) is a max. of 1.5 m,
but may be reduced in metallic environments, particularly in magnetic fields or where
there is aluminium.
Ideally, you should perform a read range test with an authorised transponder and a
battery-operated Smart Relay.
3.5 FURTHER INFORMATION
- All cabling used to connect Smart Relay should be type IY(ST)Y ....x0.6 -
twisted pair, shielded cable - and cables should not exceed 100 m in length.
Power losses should be taken into account when dimensioning the power
supply.
- The technical data regarding inputs and outputs are to be taken into account
(see Technical Data).
- All cabling must be installed and connected as per VDE regulations (VDE =
German Association of Electro-technology, Electronics & Information Technol-
ogy).
4.0 Before installation
Unpack Smart Relay and check for any damage.
Connect Smart Relay to a power supply or a battery.
If Smart Relay is to be operated via a mains adapter, insert the backup battery
in the designated holder (see Installation of backup battery).
Check that Smart Relay functions with a transponder in its as-delivered condi-
tion.
Remove the housing if you install in a flush-fitted masonry box.
If mounted on the surface, the base plate can be used as a template for the
drill holes (6 mm).